One of the Model 1000 series of load cells

Interface Force Measurement manufactures a variety of load cells, available to Canadian businesses through Durham Instruments. For example, the Model 1000 series comprises low-profile, fatigue-rated load cells with 300 per cent safe overload, extremely low moment sensitivity of 0.1 per cent per inch, and higher fatigue life.

Each load cell in the Model 1000 series provides up to 100 million fully rendered cycles, with numerous variants and configurations.

Individually inspected and tested sensors

These fatigue-rated load cells work well for applications in a wide range of sectors. Durham Instruments recommends them for use in general manufacturing, aerospace, automation, food processing, forestry, education, the medical field, the military, mining, packaging, power generation, alternative energy, transportation, and research and development.

The Interface team inspects and tests the gauged sensors in every one of these load cells and certifies them to meet the manufacturer’s rigid standards. These cells can measure a wide spectrum of weights, from one pound to 1,000,000. Other notable features of these fatigue-rated load cells:

  • capacities from 1.25 to 225 kilonewtons;
  • proprietary Interface temperature-compensated strain gauges;
  • performance of up to 0.03 per cent;
  • eccentric-load compensation;
  • low deflection;
  • 0.0015 per cent per degree Celsius of temperature effect on output;
  • barometric compensation;
  • shunt calibration; and
  • optional E74 NIST traceable tension and compression calibration.

Interface also offers options for second-bridge, third-bridge, and overload protection. The base is highly recommended; other options available include connector protection, standardized output, a transducer electronic sheet, custom calibration, multiple bridges, special threads, a dual diaphragm, a special temperature range, various cable lengths, and a connector added to the cable.

Among the connector options: an integral cable of three metres; a PT02E-10-6P bayonet connector; or a PC04E-10-6P screw-type connector. Customers can also choose from such accessories as a mating connector, mating cable, loading hardware, and other instrumentation.

The Model 1000 series is not the only line of load cells available from Interface. Models 1010, 1020, and 1032 are alternate series of fatigue-rated, low-profile cells. Other popular options include the WTS 1200 model and the 1600 Gold Standard.

To learn more, contact Durham Instruments.